foofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofooairporthospitalsindustrylogisticsretailArtboardempowermentinnovationbrochureproductpassionproductsrespectteamworkArtboard@2xwhitepaperwiring-diagramsfacebookinstagramlinkedintwitteryoutubearrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

FLY

Passive infrared sensor for automatic doors
Technology Passive Infrared
Colours:
FLY passive infrared sensor for small automatic doors

Description

Small passive infrared motion sensor allowing the opening of small pedestrian doors. Its small size makes it possible to conceal it completely inside a door profile. The FLY can also be installed on a door profile or in the ceiling thanks to its mounting accessories.

Features

Accurate & reliable detection field

Homogeneous lobe independent of the external temperature conditions, intensitive to air currents, sudden temperature variation and external interference such as rain, snow etc.

Easy adjustment of detection field

Adjustment of the size of the detection area is carried out by cutting segments off the masking lens. Electronic adjustments are performed by means of DIP-switches.

Table of specifications

Technology :

passive infrared and microprocessor

 

Optical characteristics:

P.I.R. with 4 elements, 15 lenses with full independent masking possibilities

 

Maximum Detection area (mounting height: 2.2m):
Minimum Detection area (mounting height: 2.2 m)

2.5 m (W) x 1.5 m (D)
0.5 m (W) x 0.5 m (D)

 

Detection mode:

motion

 

Detection speed:

0.1 to 1.5 m/s

 

LED-signal:

1 red LED:flashes for a few seconds after power-on
LED lights up: sensor detects motion

 

Warm-up time:

10 s

 

Hold time:

0.5 s ou 2 s

 

Response time:

< 200 ms

 

Power supply:

12 VDC - 10% à 24VDC +30% /12 to 24 V AC ±10%

 

Frequency:

50/60 Hz

 

Power consumption:

< 1 W

 

Connection:

terminal block

 

Recommended cable section (terminal block):

< 0.5 mm²

 

Standard output:
Max. contact voltage:
Max. contact current:
Max. switching power:

relay (free potential contact)
60 V DC / 42 V AC
1A (resistive)
30W (DC) / 42 VA (AC)

 

Mounting height:

3 m max

 

Temperature range:

from -30 °C to +55 °C

 

Dimensions FLY:
Dimensions FCA:
Dimensions FSA:

101 mm (W) x 41 mm (H) x 27 mm (D)
91 mm (W) x 40 mm (H) x 40 mm (D)
121 mm (W) x 51 mm (H) x 40 mm (D)

 

Color (FLY-FCA-FSA):

anthracite grey

 

Length of cable:

2.5 m

 

Normconformity:

EN 61000-6-2; EN 61000-6-3; EN 50581

 

Specifications are subject to changes without prior notice – Measured in specific conditions.

Versions
  • FLY passive infrared sensor for small automatic doors
    FLY

    sensor only

  • FLY surface mounting adapter
    FLYCATCHER

    FLY + FSA

  • FLY ceiling adapter
    FLYUP

    FLY + FCA

Accessories
Downloads
need more information Contact us